News The current location: Home > News > New update to Manual type of surface tension meter model A3

New update to Manual type of surface tension meter model A3

Number of hits:14910    Release time:2020-08-25 00:00:00

Surface tensiometer model A3 is manual standard version standalone instrument that equipped with analytical balance and high precise positioning stage. It can be used to measure surface tension of liquids based on Wilhelmy plate and Du Noüy ring methods rapidly and simply.

Typical fields of application to surface tension meter A3
- Teaching experiment for demonstrating the method for measurement of surface tension
- Quality control: ink, paint, plating fluid, cosmetics and transformer oils, etc.
- Detergent ~ surfactant’s absorbing speed, property, discussion of proper concentration

Performance Features  of surface tension meter A3

² First type of the world that measures surface tension using Wilhelmy plate manually.

² Long and best seller model with reasonable price and specifications

² Analytical balance with fast data update speed and positioning stage with accuracy of 0.01mm eliminates personal error

² Analytical balance provides higher precise than weighing unit using torsion wire

² Measuring result is real time LED digital readout

² Simple operations with manual and simple calibration with standard weights (50g)

² 3th generation Wilhelmy Plate method presents you the performances below.:

Variations of surface tension over time in the presence of surfactant.

Surface tension of medium-to high viscosity liquids (up to about 104105 CP.s)

² Possessing both Wilhelmy plate method and Du Noüy ring methods (Latter method needs manual calculating by Excel file provided from us)

² Standalone. Need not connect to PC.

 

Technical Specifications of surface tension meter A3 

 

 

Measurement method:

Wilhelmy Plate method / Du Noüy Ring method (option)

Measurement range:

0~999.9 mN/m

Max load:

50g

Resolution:

0.1mN/m

Accuracy:

± 1mN/m

Sample stage:

High precise positioning stage

Resolution of stage positioning:

0.01mm

Travel distance:

10mm

Data display:

Digital on LED

Measuring time:

1~3 sec. after touching interface (low viscous liquid sample)

Measuring temperature:

Ambient temp.

Sample volume:

min. 15mL or (1mL sample vessel made of PTFE for option)

Data output:

N.A.

Power supply:

Standard AC100-220V, 50-60Hz, 48W

Dimensions

190 W x 250D x 250H mm

Weight:

5 kg

Standard Components of surface tension meter A3

 

 

l Main body

1

l Calibration weight (50g)

1

l Holder

1

l Alcohol lamp

1

l Platinum plate

1

l Forceps

1

l Glass lab. dish for surface tension

2

l Install tool

1

l Glass lab. Dish for interface tension

1

l Operation manual

1

surface tension meter model A3

Hot keywords of USA KINO:contact anglecontact angle measurement,  contact angle meter,  contact angle goniometer,  surface tensiometer, interfacial tensiometer,  surface tension measurement,  surface tension, surface tensiometry, contact angle measurement equipment and device, calculating surfac free energy, Determining Critical Micelle Concentration (CMC) of surfactant, made in China Method for choosing surface tensiometer NEW Method for choosing contact angle meter (goniometer) NEW Method for choosing interfacial tension meter NEW